Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.304
Filtrar
1.
Front Oncol ; 14: 1371405, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38562168

RESUMO

Introduction: Mandibular reconstruction with the free fibula flap (FFF) has become a standardized procedure. The situation is different with oral rehabilitation, so the purpose of this study was to investigate the frequency of implant placement and prosthetic restoration. Additionally, the patients' situation, motivation, and treatment course were structurally assessed. Materials and methods: All cases between January 2013 and December 2018 that underwent mandibular reconstruction in our department with a free fibula flap and gave written informed consent to participate were interviewed with two structured questionnaires about their restoration and quality of life. Additionally, medical records, general information, status of implants and therapy, and metric analyses of the inserted implants were performed. Results: In total 59 patients were enrolled and analyzed in this monocentric study. Overall, oral rehabilitation was achieved in 23.7% at the time of investigation. In detail, implants were inserted in 37.3% of patients and showed an 83.3% survival of dental implants. Of these implanted patients, dental implants were successfully restored with a prosthetic restoration in 63.6. Within this subgroup, satisfaction with the postoperative aesthetic and functional result was 79.9% and with the oral rehabilitation process was 68.2%. Satisfaction with the implant-borne prosthesis was 87.5%, with non-oral-squamous-cell-carcinoma patients being statistically significantly more content with the handling (p=0.046) and care (p=0.031) of the prosthesis. Discussion: Despite the well-reconstructed bony structures, there is a need to increase the effort of achieving oral rehabilitation, especially looking at the patient's persistent motivation for the procedure.

2.
J Imaging Inform Med ; 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38565730

RESUMO

This study aims to provide an effective solution for the autonomous identification of dental implant brands through a deep learning-based computer diagnostic system. It also seeks to ascertain the system's potential in clinical practices and to offer a strategic framework for improving diagnosis and treatment processes in implantology. This study employed a total of 28 different deep learning models, including 18 convolutional neural network (CNN) models (VGG, ResNet, DenseNet, EfficientNet, RegNet, ConvNeXt) and 10 vision transformer models (Swin and Vision Transformer). The dataset comprises 1258 panoramic radiographs from patients who received implant treatments at Erciyes University Faculty of Dentistry between 2012 and 2023. It is utilized for the training and evaluation process of deep learning models and consists of prototypes from six different implant systems provided by six manufacturers. The deep learning-based dental implant system provided high classification accuracy for different dental implant brands using deep learning models. Furthermore, among all the architectures evaluated, the small model of the ConvNeXt architecture achieved an impressive accuracy rate of 94.2%, demonstrating a high level of classification success.This study emphasizes the effectiveness of deep learning-based systems in achieving high classification accuracy in dental implant types. These findings pave the way for integrating advanced deep learning tools into clinical practice, promising significant improvements in patient care and treatment outcomes.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38567801

RESUMO

OBJECTIVE: This in-vitro study assessed the influence of two intraoral scanning (IOS) protocols on the accuracy (trueness and precision) of digital scans performed in edentulous arches. METHODS: Twenty-two abutment-level master casts of edentulous arches with at least four implants were scanned repeatedly five times, each with two different scanning protocols. Protocol A (IOS-A) consisted of scanning the edentulous arch before inserting the implant scan bodies, followed by their insertion and its subsequent digital acquisition. Protocol B (IOS-B) consisted of scanning the edentulous arch with the scan bodies inserted from the outset. A reference scan from each edentulous cast was obtained using a laboratory scanner. Trueness and precision were calculated using the spatial fit analysis, cross-arch distance, and virtual Sheffield test. Statistical analysis was performed using generalized estimating equations (GEEs). Statistical significance was set at α = .05. RESULTS: In the spatial fit test, the precision of average 3D distances was 45 µm (±23 µm) with protocol IOS-A and 25 µm (±10 µm) for IOS-B (p < .001), and the trueness of average 3D distances was 44 µm (±24 µm) with protocol IOS-A and 24 µm (±7 µm) for IOS-B (p < .001). Cross-arch distance precision was 59 µm (±53 µm) for IOS-A and 41 µm (±43 µm) for IOS-B (p = .0035), and trueness was 64 µm (±47 µm) for IOS-A and 50 µm (±40 µm) for IOS-B (p = .0021). Virtual Sheffield precision was 286 µm (±198 µm) for IOS-A and 146 µm (±92 µm) for IOS-B (p < .001), and trueness was 228 µm (±171 µm) for IOS-A and 139 µm (±92 µm) for IOS-B (p < .001). CONCLUSIONS: The IOS-B protocol demonstrated significantly superior accuracy. Placement of scan bodies before scanning the edentulous arch is recommended to improve the accuracy of complete-arch intraoral scanning.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38567929

RESUMO

OBJECTIVES: This RCT aimed to compare zirconia and titanium dental implants in the maxillary premolar region. The comparison was based on marginal bone level (MBL) changes, clinical parameters, aesthetic outcomes, and patient related outcome measures (PROMs) 1 year after prosthetic loading. MATERIALS AND METHODS: Fifty patients were randomly assigned to receive either a zirconia (ZrO2, n = 25) implant or a titanium (Ti, n = 25) bone-level implant. Implants were provided with a lithium disilicate crown 3 months after placement. Follow-up was at 1 month and after 1 year. The primary outcome pertained to changes in MBL. Reported secondary outcomes consisted of implant survival, peri-implant tissue health, aesthetics, and PROMs. RESULTS: Mean MBL change after 1 year was 0.01 mm (SD = 0.45; min = 0.72, max = 0.86) for ZrO2 and -0.09 mm (SD = 0.34; min = 0.53, max = -1.06) for Ti (p = .439). Scores for the other clinical outcome parameters and PROMs were generally favorable, with no significant differences. However, significant differences were found for the aesthetic outcomes regarding two criteria: (a) level of facial mucosa (p = .022), in favor of Ti, and (b) root convexity/soft tissue color and texture (p = .005) in favor of ZrO2. CONCLUSION AND CLINICAL IMPLICATIONS: The ZrO2 and Ti implant types used in this study, replacing a single missing maxillary premolar, show a comparable outcome in terms of MBL change after 1 year. Clinical and aesthetic parameters, as well as PROMs, are favorable and similar between both implant types after 1 year of prosthetic loading. These short-term study results suggest that both are suitable for clinical use.

5.
J Clin Periodontol ; 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561985

RESUMO

AIM: To apply high-frequency ultrasound (HFUS) echo intensity for characterizing peri-implant tissues at healthy and diseased sites and to investigate the possible ultrasonographic markers of health versus disease. MATERIALS AND METHODS: Sixty patients presenting 60 implants diagnosed as healthy (N = 30) and peri-implantitis (N = 30) were assessed with HFUS. HFUS scans were imported into a software where first-order greyscale outcomes [i.e., mean echo intensity (EI)] and second-order greyscale outcomes were assessed. Other ultrasonographic outcomes of interest involved the vertical extension of the hypoechoic supracrestal area (HSA), soft-tissue area (STA) and buccal bone dehiscence (BBD), among others. RESULTS: HFUS EI mean values obtained from peri-implant soft tissue at healthy and diseased sites were 122.9 ± 19.7 and 107.9 ± 24.7 grey levels (GL); p = .02, respectively. All the diseased sites showed the appearance of an HSA that was not present in healthy implants (area under the curve = 1). The proportion of HSA/STA was 37.9% ± 14.8%. Regression analysis showed that EI of the peri-implant soft tissue was significantly different between healthy and peri-implantitis sites (odds ratio 0.97 [95% confidence interval: 0.94-0.99], p = .019). CONCLUSIONS: HFUS EI characterization of peri-implant tissues shows a significant difference between healthy and diseased sites. HFUS EI and the presence/absence of an HSA may be valid diagnostic ultrasonographic markers to discriminate peri-implant health status.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38563550

RESUMO

OBJECTIVE: The objective was to assess the one year implant treatment outcome and patient-related outcome measures (PROMs) following maxillary sinus floor augmentation (MSFA) with autogenous bone graft (ABG) from the zygomatic buttress (control) compared with 1:1 mixture of ABG and anorganic porcine bone mineral (APBM) (Test I) or biphasic bone graft material (BBGM) (Test II). MATERIALS AND METHODS: Sixty healthy patients (34 females, 26 males) were randomly allocated to either control or test groups. Outcome measures included survival of suprastructures and implants, implant stability quotient, health status of peri-implant tissue, peri-implant marginal bone loss, frequency of complications, and PROMs using Oral Health Impact Profile-14 combined with questionnaire assessing patient perception of peri-implant soft tissue, prosthetic solution, implant function, and implant treatment outcome using visual analogue scale. Mean differences were expressed with standard deviation and 95% confidence interval. Level of significance was .05. RESULTS: All suprastructures and implants were well-functioning after one year of functional implant loading. There was no significant difference between control and test groups in any of the applied outcome measures. The implant stability significantly increased from implant placement to abutment connection within all groups (p < .001). High patient satisfaction and significant improvement in oral health-related quality of life was also reported within all groups. CONCLUSION: This study demonstrates that MSFA with composite grafts containing minimal amounts of ABG reveals comparable implant treatment outcomes as compared with ABG alone, after one year of functional implant loading. Extensive ABG harvesting in conjunction with MSFA therefore seems not to be needed.

7.
Front Dent ; 21: 2, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38571900

RESUMO

Conventional obturator prostheses might cause dissatisfaction in patients with hard or soft palate defects due to inadequate retention and function during speech, mastication, and swallowing. Thus, surgical reconstruction and implant-supported obturators are considered as alternative treatments for these patients. This case-report study describes the prosthetic reconstruction of an 88-year-old patient suffering from a hard palate defect after surgical resection of verrucous carcinoma in the left side of the hard palate. Fifteen months after radiotherapy, two implants were placed in the right side of the remaining ridge, in the second and third molar region. After the implant healing period, the implant-supported obturator prosthesis was fabricated. The patient was satisfied with the esthetics and function of the obturator at the 12-month recall visit and radiographs showed normal healing and no bone loss around the implants.

8.
J Pharm Bioallied Sci ; 16(Suppl 1): S60-S62, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595361

RESUMO

Natural products have received a lot of attention in a variety of medical sectors, including dentistry. Cissus, a flowering plant genus, has long been used for its therapeutic benefits. The purpose of this review is to thoroughly investigate the possibilities of Cissus extracts in dentistry. To that end, we used specific selection criteria for the selection of pertinent scientific articles published in the scientific information databases of PubMed, Web of Science, Google Scholar, Scopus, and ProQuest. We found that the diverse array of bioactive compounds found in varied species of Cissus holds promise for applications ranging from oral wound healing to periodontal health. This review summarizes known studies on antibacterial, anti-inflammatory, and tissue-regenerative characteristics of Cissus extracts, shedding light on their potential significance in modernizing modern dental practices. It exerts that Cissus extracts have the potential to supplement established dentistry therapies by providing all-natural remedies for a variety of oral health conditions.

9.
J Pharm Bioallied Sci ; 16(Suppl 1): S886-S888, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595393

RESUMO

Background: Dental implant surgery has become a widely accepted method for replacing missing teeth. However, the success of dental implant procedures can be influenced by various factors, including the quality of preoperative planning and assessment. Cone beam computed tomography (CBCT) imaging provides valuable insights into a patient's oral anatomy, but accurately predicting implant success remains a challenge. Materials and Methods: In this randomized controlled trial (RCT), a cohort of 150 patients requiring dental implants was randomly divided into two groups: an artificial intelligence (AI)-assisted group and a traditional assessment group. Preoperative CBCT images of all patients were acquired and processed. The AI-assisted group utilized a machine learning model trained on historical data to assess implant success probability based on CBCT images, while the traditional assessment group relied on conventional methods and clinician expertise. Key parameters such as bone density, bone quality, and anatomical features were considered in the AI model. Results: After the completion of the study, the AI-assisted group demonstrated a significantly higher implant success rate, with 92% of implants successfully integrating into the bone compared to 78% in the traditional assessment group. The AI model showed an accuracy of 87% in predicting implant success, whereas traditional assessment methods achieved an accuracy of 71%. Additionally, the AI-assisted group had a lower rate of complications and required fewer postoperative interventions compared to the traditional assessment group. Conclusion: The AI-assisted approach significantly improved implant success rates and reduced complications, underscoring the importance of incorporating AI into the dental implant planning process.

10.
J Pharm Bioallied Sci ; 16(Suppl 1): S564-S566, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595415

RESUMO

Background: Tooth extraction often results in bone loss in the alveolar ridge, which can complicate subsequent dental implant placement. Alveolar ridge preservation (ARP) techniques, such as bone grafting, aim to mitigate this bone loss. Platelet-rich plasma (PRP) has been proposed as an adjunct to bone grafting in ARP to enhance bone regeneration. Materials and Methods: A total of 60 patients requiring tooth extraction and ARP were included in this randomized controlled trial. Patients were divided into two groups: Group A received bone grafting alone, while Group B received bone grafting with PRP. Clinical and radiographic assessments were performed at baseline and 6-month postsurgery. Bone density and height were measured using arbitrary values. Results: At the 6-month follow-up, Group B demonstrated a statistically significant increase in bone density (P < 0.05) and bone height (P < 0.05) compared to Group A. The arbitrary values for bone density in Group B increased by 15% and bone height increased by 10% compared to baseline measurements. Group A showed minimal improvement. Conclusion: The incorporation of PRP as an adjunct to bone grafting in ARP following tooth extraction significantly enhances bone density and height, suggesting its efficacy in preserving the alveolar ridge.

11.
J Pharm Bioallied Sci ; 16(Suppl 1): S792-S793, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595421

RESUMO

Objective: The current research was done to assess microbial seepage of two types of internal implant-abutment connections. Materials and Methods: Twenty dental implants are categorized into two groups. Group A fixtures with an internal hexagonal geometry and group B fixtures with a tri-lobe internal connection. All implant-abutment assemblies underwent a three-week incubation period at 37°C in sterile tubes containing 5 mL of Staphylococcus aureus broth culture. Through the use of Gram stain and biochemical processes, the resultant colonies were recognized. Results: The mean Log10 colony forming unit (CFU) in group A was 8.4 and in group B was 7.2. The variation between both groups was found to be considerable (P < 0.05). Microgap was more in group B compared to group A. Conclusion: Bacteria may infiltrate the small area between the implant and the abutment. Compared to dental implant fixtures with a tri-lobe internal connection, there was a noticeably higher Log10 CFU in dental implant fixtures with an internal hexagonal geometry.

12.
J Pharm Bioallied Sci ; 16(Suppl 1): S847-S849, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595515

RESUMO

Background: Dental implantology has witnessed substantial progress in recent years, driven by a growing emphasis on optimizing bone regeneration around dental implants. Nanoparticles have emerged as a potential tool for enhancing osseointegration and bone tissue regeneration. Materials and Methods: This human clinical trial enrolled 60 adult participants requiring dental implants. Patients were randomly assigned to one of two groups: a control group receiving conventional dental implants, and an experimental group receiving dental implants with nanoparticle-coated surfaces. Radiographic imaging, histological analysis of bone biopsies, and implant stability assessments were conducted at three and six months post-implantation. Results: Histological examination of bone biopsies revealed a statistically significant increase in new bone formation in the experimental group compared to the control group at both three and six months (P < 0.05). Radiographic assessment demonstrated a 25% higher bone density around nanoparticle-coated implants (P < 0.01) at the six-month mark. Implant stability quotient (ISQ) measurements indicated a 20% greater stability in the experimental group (P < 0.05) at the same time point. Conclusion: This human clinical trial provides strong evidence that the incorporation of nanoparticles on dental implant surfaces enhances bone regeneration and osseointegration in a human population.

13.
J Pharm Bioallied Sci ; 16(Suppl 1): S477-S479, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595584

RESUMO

This study addresses the durability and complications of zirconia dental implants through a prospective clinical investigation. Zirconia implants are increasingly utilized in dental implantation, and a comprehensive understanding of their long-term performance is essential. Background: Zirconia dental implants have gained attention due to their biocompatibility and aesthetics. However, research on their extended success and complication rates is limited. Materials and Methods: A prospective clinical study involved the placement of 30 zirconia dental implants in patients requiring tooth replacement. The implants were followed up for five years. Success was defined as the implant remaining stable and functional. Complications, including peri-implant mucositis and peri-implantitis, were monitored. Statistical analysis included descriptive statistics, Chi-square test, and P-values were set at P < 0.05. Results: The long-term success rate of zirconia dental implants was found to be 93.3%. Among the 30 implants, only 2 exhibited failure. The most common complication was peri-implant mucositis, occurring in 16.7% of implants. Notably, the incidence of peri-implantitis was limited, observed in 6.7% of implants. Statistical analysis showed significant associations between implant failure and smoking (P = 0.021). Conclusion: Zirconia dental implants demonstrated a high long-term success rate of 93.3% over five years. Peri-implant mucositis was the predominant complication, with a relatively low occurrence of peri-implantitis. The findings underscore the potential of zirconia implants for reliable dental implantation. Addressing modifiable risk factors, such as smoking, could further enhance implant success. Continued research is recommended to validate and expand upon these outcomes.

14.
J Pharm Bioallied Sci ; 16(Suppl 1): S192-S195, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595601

RESUMO

Objective: Purpose: To evaluate the efficacy of water flossing to traditional flossing in lowering the bleeding on probing (BOP) index around dental implants. Methods and Materials: This single-center, examiner-masked research enrolled patients with implants and randomly allocated them to one of two groups. The research analyzed the effectiveness of manual toothbrushes when used with either string floss or a water flosser. Results: After 30 days, the main result was a decrease in BOP occurrence. At the outset, neither group had noticeably higher rates of bleeding than the other. While only six of 20 implants in the floss group demonstrated a decrease in BOP after 30 days, 18 of 20 implants in the water flosser group did. Conclusions: These results demonstrate that the use of water flossers was associated with much less bleeding than that of string floss. The researchers think that water flossing might be a useful addition to the maintenance of dental implants.

15.
J Pharm Bioallied Sci ; 16(Suppl 1): S446-S448, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595602

RESUMO

Background: This randomized controlled trial aimed to compare the aesthetic outcome and patient perception of immediate versus DL of implant-supported single crowns. Methods: A total of 60 patients with a single missing tooth were enrolled and randomly assigned to two groups: immediate loading (IL) and delayed loading (DL). Each group consisted of 30 patients with a total of 30 implants. In the IL group, crowns were loaded onto implants immediately after placement, while in the DL group, a healing period of 3 months was observed before crown placement. Aesthetic outcome was assessed using the Pink Esthetic Score (PES) for soft tissue and the White Esthetic Score (WES) for the crown. Patient perception was evaluated through a visual analog scale (VAS) for satisfaction, comfort, and overall experience. Results: The IL group demonstrated comparable aesthetic outcomes to the DL group, with mean PES and WES scores of 10.2 ± 1.5 and 8.7 ± 1.2, respectively, in the IL group, and 10.5 ± 1.3 and 8.5 ± 1.4 in the DL group. Patient perception in terms of satisfaction, comfort, and overall experience was similarly high in both groups, with VAS scores above 8 for each parameter. Conclusion: This randomized controlled trial suggests that both IL and DL of implant-supported single crowns result in favorable aesthetic outcomes and high levels of patient satisfaction.

16.
J Prosthodont ; 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600720

RESUMO

Traditionally, artificial teeth arrangements or the definitive complete dentures are used to establish important prosthodontic parameters such as the occlusal plane orientation, vertical dimension, and the incisal edge position. The relationship of these elements with the underlying bony structures is commonly evaluated using advanced planning protocols such as the dual scan technique. This technique article presents an uncomplicated alternative approach to establish these parameters intraorally using a 3D-printed shell complete denture generated from a 3D scan of the patient's existing complete denture.

17.
J Oral Implantol ; 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38600837

RESUMO

Various factors influence marginal bone loss following implant placement. This study explored the association between marginal bone loss and posterior implants positioned at different bone levels. Computer records and radiographs of patients with at least two adjacent implants were retrieved. Cases were categorized into non-splinted prosthesis and splinted prosthesis groups. Radiographic measurements were conducted at the time of abutment placement (T0), 1-3 years follow-up (T1), and the last visit (T2), measuring the vertical distance between adjacent implants. Multilevel linear regression models using generalized estimating equations were employed, with a significance level set at 5% (α=0.05). Fifty-six patient records were included, comprising 120 implants: 84 non-splinted (70%) and 36 splinted (30%). In the non-splinted group, marginal bone loss progression significantly depended on crestal height differences. For the mesial sides of posterior implants, marginal bone loss measured 1.0 ± 0.6 mm from T0 to T1, 2.4 ± 1.1 mm from T1 to T2, and 3.4 ± 1.2 mm from T0 to T2. Similarly, the distal sides of the most anteriorly placed implant exhibited marginal bone loss of 1.0 ± 0.7 mm from T0 to T1, 2.4 ± 1.0 mm from T1 to T2, and 3.5 ± 1.2 mm from T0 to T2. Non-splinted implants demonstrated a higher progression of marginal bone loss. This study suggests that non-splinted implants may lead to a more pronounced progression of marginal bone loss, particularly concerning crestal height differences, underscoring the need for further research.

18.
J Periodontal Res ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594821

RESUMO

This image article presents a single patient receiving a reconstructed fibular bony peak (BP) for guided bone regeneration (GBR) with a customized titanium mesh. The patient was informed and understood the objectives and signed a written informed consent document before surgery.

19.
J Prosthodont ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594924

RESUMO

PURPOSE: Bioceramic coatings have been shown to promote bone repair, which aids in the early integration of implants. This study aimed to evaluate the influence of air abrasion with a bioceramic abrasive on the surface characteristics of different implant materials and surfaces. The dissolution of the applied treatment from the surfaces over 3 weeks was also assessed. MATERIALS AND METHODS: Discs of three alloys used for dental implants were studied and compared: two types of commercially pure titanium (CpTi)/ (CpTi SLActive) and titanium-zirconia (TiZr). The tested surfaces were: CpTi control (CpC), sandblasted (SB), sandblasted and acid-etched (SBE), and CpTi SLActive®, (TiZr) Roxolid®. Three discs from each group underwent air abrasion with apatite bioceramic powders, 95% hydroxyapatite (HA)/5% calcium oxide (CaO), and 90% hydroxyapatite (HA)/10% calcium oxide (CaO). The treated discs were surface characterized by optical profilometry to obtain surface roughness, scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS) to compare element weight percentages of titanium, calcium, and phosphate. Dissolution was assessed using inductively coupled plasma optic emission spectrometry (ICP-OES). RESULTS: Bioceramic powders were deposited on all tested surfaces leading to changes in surface characteristics. The only statistically significant differences between the material groups for surface roughness were found with 95% HA/5% CaO powder in the Sp and Rp parameters (p = 0.03 and 0.04, respectively). There were no significant differences in the Ca and P wt% between all groups and powders 95% HA/5% CaO and 90% HA/10% CaO (p = 0.14, 0.18, and p = 0.15, 0.12, respectively). A non-uniform dispersion of the treatment on the surface layer was visible on all treated surfaces. The bioceramic powder continued to dissolute from the tested surfaces for 3 weeks. CONCLUSION: Bioceramic abrasion modifies implant surface characteristics, although the change in surface characteristics resulting from such treatment was not influenced by the implant material or surface treatment. Air abrasion with hydroxyapatite and calcium oxide bioceramics leaves powder deposits on the treated implant surfaces that could potentially influence the healing of implants affected by peri-implantitis.

20.
J Esthet Restor Dent ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38591169

RESUMO

OBJECTIVES: To evaluate clinical, clinician- and patient-reported outcomes (PROs) of two adjacent single posterior implants immediately loaded with definitive single crowns up to 1 year. Ten patients in need of two adjacent posterior single implants were included. All implants were placed applying a fully digital workflow. Definitive screw-retained single zirconia crowns were delivered within 72 h after implant placement. Clinical parameters, patient- and clinician-reported outcomes were assessed up to 1 year of follow-up. CLINICAL CONSIDERATIONS: Clinical outcomes remained stable, with no implant failures or technical and biological complications throughout the observation period. Patient satisfaction was very high at baseline (crown delivery) and remained consistently high at 6 and 12 months of follow-up. Crown insertion 3 days after implant placement was rated as an easy procedure by clinicians. CONCLUSIONS: Two adjacent single implants with immediate definitive restorations (<72 h) in the posterior region appear to be a viable and easy treatment option to shorten the overall treatment time and potentially enhancing patient satisfaction. However, randomized controlled trials are needed to confirm the advantages of this treatment protocol over a delayed loading approach. CLINICAL SIGNIFICANCE: In selected cases, immediate implant loading with definitive restorations in the posterior region appears a valuable and straightforward option to shorten the overall treatment time.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...